Journal Information
Vol. 211. Issue 2.
Pages 69-75 (February 2011)
Share
Share
Download PDF
More article options
Vol. 211. Issue 2.
Pages 69-75 (February 2011)
Original
Troponina-I en el tromboembolismo pulmonar hemodinámicamente estable: correlación con la ecocardiografía y la angiografía por tomografía computarizada
Troponin-I in hemodynamically-stable pulmonary embolism: correlation with echocardiography and computed tomography angiography
R. Golpea,
Corresponding author
, L.A. Pérez-de-Llanoa, O. Castro-Añóna, M. Vázquez-Carunchob, C. González-Juanateyc, M.C. Fariñasd
a Servicio de Neumología, Complexo Hospitalario Xeral-Calde, Lugo, España
b Servicio de Radiología, Complexo Hospitalario Xeral-Calde, Lugo, España
c Servicio de Cardiología, Complexo Hospitalario Xeral-Calde, Lugo, España
d Departamento de Medicina Interna, Hospital Universitario Marqués de Valdecilla, Santander, España
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (4)
Tabla 1. Diferencias entre pacientes en que se midió y no se midió la TnI.
Tabla 2. Comparación entre pacientes con TnI elevada e indetectable.
Tabla 3. Correlación entre TnI y parámetros ecocardiográficos y radiológicos.
Tabla 4. Comparación de parámetros ecocardiográficos y radiológicos entre pacientes con TnI elevada e indetectable.
Show moreShow less
Resumen
Antecedentes

La troponina-I (TnI) es un marcador de gravedad en pacientes no seleccionados con tromboembolismo pulmonar (TEP). Hay pocos trabajos que valoren su utilidad en pacientes hemodinámicamente estables.

Objetivos

valorar la correlación entre los niveles de TnI y la existencia de signos ecocardiográficos y radiológicos de disfunción de ventrículo derecho (VD) o de hipertensión pulmonar (HTP), así como con la intensidad de la obstrucción vascular.

Métodos

Se seleccionaron pacientes de un estudio prospectivo previo que incluyó 103 sujetos consecutivos con TEP y presión arterial sistémica ≥ 90 mmHg, realizándose en todos los casos angiografía por tomografía computarizada (TC) y ecocardiograma. Se realiza un estudio post hoc, en el que se analizan los 68 casos en que, según el criterio clínico del facultativo de urgencias, se realizó medición de TnI.

Resultados

Mediana de edad: 74 años. El 50% eran varones. Los pacientes con elevación de la TnI presentaron un perfil clínico diferenciado, sugestivo de TEP más grave. Existió una correlación significativa entre los niveles de TnI y la presión arterial pulmonar sistólica (r=0,46, p<0,001), el diámetro de la arteria pulmonar (r=0,48, p<0,001) y del VD (r=0,47, p=0,001) medidos por TC, y el índice de obstrucción vascular pulmonar (r=0,39, p=0,001).

Conclusión

En pacientes con TEP hemodinámicamente estable, los niveles más elevados de TnI predicen la existencia de un TEP más grave, y podrían usarse en la práctica clínica para seleccionar a aquellos pacientes que precisan un seguimiento clínico, o mediante pruebas complementarias, más estrecho.

Palabras clave:
Embolismo pulmonar
Troponina I
Ecocardiografía
Tomografía computarizada
Función del ventrículo derecho
Abstract
Background

Troponin-I (TnI) is a marker of severe pulmonary thromboembolism (PTE) in unselected patients. There are few articles that assess its usefulness in hemodynamically-stable patients.

Objectives

To assess the correlation between TnI levels and both echocardiographic/radiologic signs of right ventricle (RV) dysfunction or pulmonary hypertension (PH), and the severity of the pulmonary vascular obstruction.

Methods

We selected patients from a prospective cohort of 103 consecutive patients with PTE and systolic arterial pressure ≥ 90 mmHg. Computed tomography pulmonary angiography (CTPA) and echocardiography were performed in all patients. We performed a post hoc study, analyzing the 68 cases in which TnI was measured, at the discretion of the emergency room physician.

Results

Patients included had a median age of 74 years and 50% were male. The patients with elevated TnI had a differentiated clinical profile, suggestive of more severe PTE. There was a significant correlation between TnI levels and systolic pulmonary artery pressure (r=0.46, P<.001), the CTPA-measured pulmonary artery diameter (r=0.48, P<.001), the CTPA-measured RV diameter (r=0.47, P=.001) and the pulmonary vascular obstruction index (r=0.39, P=.001).

Conclusion

The higher levels of TnI in patients with hemodynamically stable PTE predicts the existence of more severe PE in hemodynamically-stable patients. This biomarker could be used in the clinical practice to select those patients who might require more intensive monitoring or additional complementary studies.

Keywords:
Pulmonary embolism
Troponin I
Echocardiography
Computed tomography
Right ventricular function

Article

These are the options to access the full texts of the publication Revista Clínica Española (English Edition)
Member
Si es usted socio de FESEMI siga los siguientes pasos:

Diríjase desde aquí a la web de la >>>FESEMI<<< e inicie sesión mediante el formulario que se encuentra en la barra superior, pulsando sobre el candado.

Una vez autentificado, en la misma web de FESEMI, en el menú superior, elija la opción deseada.

>>>FESEMI<<<

Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Revista Clínica Española (English Edition)

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
Email
Idiomas
Revista Clínica Española (English Edition)
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?